Reported risk: On certain school buses, a double battery (24 volt) jump start or electrical load dump could result in an overvoltage condition of the linear power module (LPM) which is used to control the heater/air conditioning blower motor speed. If this were to occur, this overvoltage condition could lead to the LPM overheating, causing smoke, and increase the risk of fire, which could result in injury and/or damage to property. Correction: Dealers will replace the LPM with an upgraded design.
Verify each fact at the issuing agency before acting. Recall scope, affected lots, and remediation instructions may be updated by the agency after our last sync.
ProductGuru indexes recall and safety-alert records from ~30 public agency registries. We are not lawyers, regulators or product-safety consultants. This page restates what the named agency published; consult the primary source above (or qualified counsel in your jurisdiction) before any commercial, medical or safety decision.