Recall A12/1611/16 — 1) 144 LED VILÁGIT; 2) 184 LED VILÁGIT

EU Safety Gate (RAPEX) · Hungary · 2016-12-09 · Serious risk

AI-assisted, human-edited — this page is drafted with AI from public-source data, then reviewed before publication. How we use AI →
Agency
EU Safety Gate (RAPEX)
Recall identifier
A12/1611/16
Date of alert
2016-12-09
Country / jurisdiction
Hungary
Risk level
Serious risk
Risk type
Electric shock, Fire
Brand
Unknown
Product category
Lighting chains
Product type
Lighting chains
Reported risk: null The cross-sectional area of the external and internal wires is too small and the wires could overheat. The wire ends soldered to the terminals of the control unit and the LEDs are not adequately protected against pulling and twisting. The socket of the extension lead enables single-pole insertion of a plug with the free remaining live pin accessible. The accessible wires can come into contact with sharp edges of the control unit and could be damaged. The product is not protected against moisture yet is recommended for outdoor use.The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60598.
Primary source: https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/237640

Verify each fact at the issuing agency before acting. Recall scope, affected lots, and remediation instructions may be updated by the agency after our last sync.

ProductGuru indexes recall and safety-alert records from ~30 public agency registries. We are not lawyers, regulators or product-safety consultants. This page restates what the named agency published; consult the primary source above (or qualified counsel in your jurisdiction) before any commercial, medical or safety decision.