DC power supply (DC power supply) — recall K25/EP/00004
OECD Global Recalls — Korea · Korea (Republic of) · 2025-02-27
🏛Compiled from an official source — the facts on this page are reproduced from the issuing authority’s own published notice, which is linked above. No AI-generated text appears on this page. How we use AI →
Agency
OECD Global Recalls — Korea
Recall identifier
K25/EP/00004
Date of alert
2025-02-27
Country / jurisdiction
Korea (Republic of)
Product category
direct current
Product type
direct current
Reported risk: ㅇ Inadequate temperature rise - Transformer (T1)@AC 198V 60 Hz (Measured) 112.3 ℃, (Allowable level) 110 ℃ or below - Transformer (T1)@AC 242V 60 Hz (Measured) 114.5 ℃, (Allowable level) 110 ℃ or below ㅇ Inadequate labelling - The output rating is labelled differently from when it was certified - After-sales contact and manufacturing date missing ◇ Risk of product-caused fire if the temperature exceeds the standard temperature
Verify each fact at the issuing agency before acting. Recall scope, affected lots, and remediation instructions may be updated by the agency after our last sync.
ProductGuru indexes recall and safety-alert records from ~30 public agency registries. We are not lawyers, regulators or product-safety consultants. This page restates what the named agency published; consult the primary source above (or qualified counsel in your jurisdiction) before any commercial, medical or safety decision.