Product Wiki · Recalls · OECD Global Recalls — Korea

Dimmer (Switch) — recall K24/EP/00017

OECD Global Recalls — Korea · Korea (Republic of) · 2024-02-29

Compiled from an official source — the facts on this page are reproduced from the issuing authority’s own published notice, which is linked above. No AI-generated text appears on this page. How we use AI →
Agency
OECD Global Recalls — Korea
Recall identifier
K24/EP/00017
Date of alert
2024-02-29
Country / jurisdiction
Korea (Republic of)
Product category
circuit
Product type
circuit
Reported risk: ㅇ Inadequate protection against electric shock - (Allowable level for creepage distance) 3 mm or above / (Measured value) Metal frame that supports the embedded switch: 1.2 mm, Metal part that could be potentially touched by human: 1.2 mm - (Allowable level for clearance distance) 3 mm or above / (Measured value) Metal frame that supports the embedded switch: 1.2 mm ㅇ Inadequate creepage distance and clearance distance from filling compounds - (Allowable level for creepage distance) 3 mm or above / (Measured value) Ground’s metal part including its circuit: 1.2 mm, Metal frame that supports the embedded switch: 1.2 mm, Metal part that could be potentially touched by human: 1.2 mm - (Allowable level for clearance distance) 3 mm or above / (Measured value) Metal frame that supports the embedded switch: 1.2 mm ◇ Risk of electric shocks if conductive parts are touched when insulation distance is short
Primary source: http://www.safetykorea.kr/recall/ajax/recallBoard?recallUid=10020050

Verify each fact at the issuing agency before acting. Recall scope, affected lots, and remediation instructions may be updated by the agency after our last sync.

ProductGuru indexes recall and safety-alert records from ~30 public agency registries. We are not lawyers, regulators or product-safety consultants. This page restates what the named agency published; consult the primary source above (or qualified counsel in your jurisdiction) before any commercial, medical or safety decision.