OECD Global Recalls — Korea · Korea (Republic of) · 2017-04-26
🏛Compiled from an official source — the facts on this page are reproduced from the issuing authority’s own published notice, which is linked above. No AI-generated text appears on this page. How we use AI →
Agency
OECD Global Recalls — Korea
Recall identifier
K17/EP/00055
Date of alert
2017-04-26
Country / jurisdiction
Korea (Republic of)
Product category
cushion
Product type
cushion
Reported risk: ○The most important defect 1. Temperature rise Measured surface temperature standard: the temperature is allowed to exceed 50 ℃ for up to 2 hours but not 85 ℃. (this period starts from when the temperature first exceeds 50 ℃) standard: 85 ℃ (within 2hours) measured: 91 ℃ (within 2hours) standard: 50 ℃ (after 2hours) measured: 54.3 ℃ (after 2hours) ○Results of equality test (change of major parts) 1. Difference in thermal cut-out
Verify each fact at the issuing agency before acting. Recall scope, affected lots, and remediation instructions may be updated by the agency after our last sync.
ProductGuru indexes recall and safety-alert records from ~30 public agency registries. We are not lawyers, regulators or product-safety consultants. This page restates what the named agency published; consult the primary source above (or qualified counsel in your jurisdiction) before any commercial, medical or safety decision.